Chủ Nhật, 24 tháng 2, 2013

Tempsens container glass industry - LGP Vietnam

Bộ điều khiển nhiệt độ AST P-120 Tempsens - www.lamgiaphu.com
Thiết bị đo nhiệt độ Tempsens India - LGP Co.,Ltd
Đầu dò nhiệt độ hãng Tempsens - Đại lý phận phối Tempsens
Thermocouples Tempsens - www.lamgiaphu.com
Can nhiệt Tempsens India - LGP Vietnam distributor
Tempsens Instruments (I) Pvt. Ltd - LGP Vietnam distributor

Base Metal Thermocouples
Technical Details
High accurate Thermocouples for variety of application
Type
J, K, T, E, N
Element size (MI)
1, 1.5, 3, 4.5, 6.8 (mm)
(Non-MI)
1.2, 1.6, 2, 2.5, 3.2 (mm)
Protection Sheath M
Seamless SS 316, SS 310, HRS 446,
INCONEL, Nickel, Hastalloy, Titanium, Ceramic, Silicon Carbide Monel etc.
Configuration
Simplex / Duplex / Multipoints

Tempsens offers three basic types of base metal thermocouples:- insulated wire, bare and ceramic insulated elements and thermocouples with protection tubes.
The base-metal thermocouple covers the majority of applications within industry over a range of –180°C to +1300°C.

Type
Names of Materials
Application Range
Iron (+)
Constantan (-)
-40 to 750°C
Chromel (+)
Alumel (-)
-200 to 1200°C
Copper (+)
Constantan (-)
-200 to 350°C
Chromel (+)
Constant (-)
-200 to 900°C
Nicorsil (+)
Nisil (-)
-200 to 1200°
LGP Vietnam distributor
Bộ điều khiển nhiệt độ AST P-120 Tempsens - www.lamgiaphu.com
Thiết bị đo nhiệt độ Tempsens India - LGP Co.,Ltd
Đầu dò nhiệt độ hãng Tempsens - Đại lý phận phối Tempsens
Thermocouples Tempsens - www.lamgiaphu.com
Can nhiệt Tempsens India - LGP Vietnam distributor
Tempsens Instruments (I) Pvt. Ltd - LGP Vietnam distributor

Special Thermocouples
Technical Details
High accurate Thermocouples for variety of application

·         Miniature Thermocouple with minimum 0.25mm Dia
·         Squzeed Thermocouple with small tip dia
·         Trilevel Thermocouple
·         Coated Thermocouple (PTFE, Tungsten Carbide, Ceramic, Steatite etc.)
·         Thermocouple with IBR Approved Thermowells
·         High Temperature Ceramic Spouts Limit
·         Special sensors as per ASTM-E235
·         W/WRe suitable upto 2300 deg c

Tempsens manufacture some special types of thermocouples to meet specific application needs and on customer demand.
Noble metal thermocouples are used for measurement of higher temperatures.


1. Squzeed Thermocouple
These thermocouples are also known as Reduced Tip Thermocouples. These thermocouples provide Fast Response and Long Life.
2. Tri-Level Thermocouple
This thermocouple is suitable for harsh environment of glass industry.
The Tri-level assembly is protected from the aggressive nature of the glass by an outer sheath of Platinum or a Platinum/Rhodium alloy and has three measuring points spaced to give readings of top, middle and bottom temperatures. This allows for accurate control of heating and cooling giving a homogeneous glass flow.
3. Coated thermocouple
Thermocouples are available with different type of coating such as Tungsten Carbide, ceramic, PTFE, PVDF, PFA Coating.
A. Tungsten coated
Thermocouple is used in a furnace. The protecting sheath when coated with a thick layer of Tungsten minimizes the carburization process and extends the life of the probes significantly.
B. PFA Coated
Probes are the perfect solution when there is a need to measure the temperature of caustic or corrosive chemical solutions in industrial and laboratory environments. The superior corrosion resistance of PFA allows you to measure the temperature of sulfuric, hydrochloric, nitric and chromic acids, as well as caustic compounds.

Applications:
·         Glass Industry
·         Steel and Iron Industry


Noble Metal Thermocouples
Technical Details
High accurate Thermocouples for variety of application
Type
R, S, B
Element size (MI)
0.30, 0.35, 0.4, 0.45, 0.5 (mm)
other on request
(Non-MI)
1.2, 1.6, 2, 2.5, 3.2 (mm)
Protection Sheath M
Ceramic (KER 710), 610,
Inconel, Silicon carbide, etc.
Configuration
Simplex / Duplex / Multipoints

Tempsens manufacture noble metal thermocouples (also called rare metal thermocouples) for many types of industries. The most common types are R, S & B rare metal thermocouple assemblies.
Noble metal thermocouples are used for measurement of higher temperatures.

Type
Names of Materials
Application Range
Platinum 13% Rhodium (+)
Platinum (-)
0 to 1600°C
Platinum 10% Rhodium (+)
Platinum (-)
0 to 1600°C
Platinum30% Rhodium (+)
Platinum 6% Rhodium (-)
600 to 1600°C

Type R thermocouple
This thermocouple is made from Platinum which is the negative leg and much softer and Platinum 13% Rhodium which is the stiffer positive leg. It is suitable for use in oxidising or inert atmospheres and may be used under reducing conditions or in a vacuum provided care is taken to ensure the refractory materials are free from siliceous materials. Pure recrystallised alumina is recommended. This thermocouple is suitable for continuous use up to 1400 C and for intermittent use up to 1650 C
Type S thermocouple
This thermocouple defines the international practical temperature scale between Antimony point (630.73 C ) and the gold point (1064.43 C). This thermocouple is made from Platinum which is the negative leg and much softer and Platinum 10% Rhodium which is the stiffer positive leg, and has the same operating requirements as type R. Again This thermocouple is suitable for continuous use up to 1400 C and for intermittent use up to 1650 C..
Type B thermocouple
This combination platinum thermocouple is made from Platinum-30% Rhodium and Platinum -6% Rhodium. When they are compared to pure platinum thermocouples they suffer less from the effects of ''Rhodium migration'' and may be used at somewhat higher temperatures, continuous operating 1500 C and up to 1800 C intermittently.

Applications:
·         Glass Industry
·         Semi-conductor Industry
·         Type S thermocouples are regularly used in the electric arc furnace process to accurately measure the steel''s temperature before tapping. The cooling curve of a small steel sample can be analyzed and used to estimate the carbon content of molten steel.

Special RTD''s















Type
Pt 100, 200, 500, 1000,
copper 50,53. etc
Element size (MI)
Wire wound ceramic encapsulated
Wire wound Glass encapsulated
Thin film ceramic encapsulated
Connection
2, 3, 4 wire
Accuracy
Class A, B 1/2, 1/3, 1/5, 1/10 DIN
Protection Sheath
SS 304, SS 316, SS 310, Inconel, Hastalloy, Monel Etc

·         Slide shoe RTDs
·         Vibration proof RTDs for DG sets
·         Motor & Transformer winding temperature RTDs
·         Handheld & Probe in various design
·         RTDs with IBR approved Thermowells
·         Strap on RTDs for nuclear
·         High Temperature RTDs upto 650°C
·         High Accuracy RTDs upto 1/10 DIN
·         Semi Standard PRTs.

Thermocouple for Furnance Crown
Product Details
It is well known that Glass Melting Furnace includes a melting chamber in which solid batch materials are heated to produce molten glass. The arch of this melting chamber is known as crown. To measure and control the temperature of furnace crown is important, because with the correct temperatures one can improve the service life of crown, as the overheating of the crown may cause of early erosion of crown refractory and the other side if the temperatures are low, it can affect the melting efficiency and will increase the fuel consumption. The highest temperature in melting furnace is at crown. To select the right materials and assembly is quit important as the temperature at crown is even more than 1600°C. The design we recommend is with dual protection sheaths. In most of the furnace thermocouples are placed in block pockets, but over a period of service it may get through hole. At crown there are number of points to measure in center, Right & Left, the same kind of assemblies can be used for Regenerator Crown as well.

Type
TI/GL/05 - A/B
Measuring Range
100 To 1600°c
Sensor Type
"R"/ "S"/ "B".
Protection Sheathing
Recrystallised Alumina KER-710 (C-799) Tube
Application
Furnace Crown , T/C Pockets,Regenerators Crown.


S.No.
Description
1.
SS/Aluminium Connection Head IP-67.
2.
SS Chain.
3.
½" NPT(M) Cable Gland.
4.
Holding Tube : (Inconel - 600/SS310).
5.
Recry. Alumina Outer Tube :- OD X ID to be specified.
6.
2/4 Bore Recry. Alumina Insulating Tube.
7.
PTRH-PT Thermocouple Element R/S/B type
8.
Inner Tube suitable to outer tube.
9.
Ceramic Fibre Insulated Compensating Cable
10.
M/F Connector


CALSys -40/200
Product Details
HIGH STABLILITY- LIQUID BATH
CALSys -40/200 is a Highly Stable Stirred Liquid Bath for calibrating RTD/Thermocouple and also for compensation of cold junction..

CALSys -40/200 offers the temperature range of -40 to 200 Deg C. It have large well which is filled with liquid (Water+Methanol /Silicon Oil). The liquid is heated or cooled to the desired temperature. Methanol+Water is used for Negative Temperature and Silicon Oil for Heating.

It has better accuracy than dry block bath due to lack of air gaps and the temperature uniformity of stirred liquid.


Specification

·         Temp Range : -40 to 200 Deg C
·         Stability : 0.01 Deg C
·         Temperature Resolution : 0.01 Deg C
·         Time to Reach Max Temp : 1.5 Hr
·         Medium Cooling : Methanol + Water
·         Medium Heating : Silicon Oil
·         Controlling Sensor : PT-100
·         Method of Control : Digital self tuned PID Controller
·         Operating Temperature : 20 to 25 Deg C
·         Power Requirement : 230 VAC, 2.0 KW
·         Dimensions : 430 x 394 x 629 mm
·         Tank Dia 280 mm x 240 mm x 140 mm (Approx)
·         Weight : Approx 54 Kg
LGP Vietnam distributor
Bộ điều khiển nhiệt độ AST P-120 Tempsens - www.lamgiaphu.com
Thiết bị đo nhiệt độ Tempsens India - LGP Co.,Ltd
Đầu dò nhiệt độ hãng Tempsens - Đại lý phận phối Tempsens
Thermocouples Tempsens - www.lamgiaphu.com
Can nhiệt Tempsens India - LGP Vietnam distributor
·         Tempsens Instruments (I) Pvt. Ltd - LGP Vietnam distributor

Key Features

·         Large Immersion Depths
·         High Accuracy
·         High Stability and Uniformity
·         Wide Temperature Range
·         PC interfacing
·         Simple to use and cost effective

Standard Accessories

Reference Standard PRT … Part No. TPRT-A-300
Operational Manual

Optional Accessories

·         Methanol…………..1L- No. (3050 - M)
·         Silicon Oil…………. 1L-Part No C200S-LB-SO






Thermocouple for Furnance Bottom
Product Details
Same as crown, to measure the correct temperatures at furnace bottom result for higher service life of bottom blocks. Bottom blocks are the costliest part of a melting tank. Bottom thermocouples are used to get efficient operation of Glass Furnace. Even 2 - 3 Degrees higher or lower temperature can affect the fuel consumption of furnace. Tempsens Thermocouples proved the "whole campaign life" goal on many projects. On this application hole can be through to immerse a glass immersion thermocouple, which will be with hardened platinum / platinum alloy thimbles over ceramic protection tubes. If the hole is blind or thermocouple pocket, the protection will be with recrystallised alumina protection sheaths.

Type
TI/GL/07 - A/B
Measuring Range
100 To 1600°c
Sensor Type
"R"/ "S"/ "B"
Protection Sheathing
Recrystallised Alumina KER-710 (C-799) Tube
Application
Furnace Crown , T/C Pockets,Regenerators.


S.No.
Description
1.
SS/Aluminium Connection Head IP-67.
2.
SS Chain.
3.
½" NPT(M) Cable Gland.
4.
Holding Tube : (Inconel - 600/SS310).
5.
Recry. Alumina Outer Tube :- OD X ID to be specified.
6.
2/4 Bore Recry. Alumina Insulating Tube.
7.
PTRH-PT Thermocouple Element R/S/B type
8.
Inner Tube suitable to outer tube.
9.
Ceramic Fibre Insulated Compensating Cable 3/6 Mtrs. long with overall ceramic fiber sleeve.
10.
Quick Release Compensated Connectors "R"/ "S"/ "B" Type.
11.
Pt. Alloy thimble (in case of glass immersion)

Calsys250
Product Details
HIGH ACCURACY LIQUID CALIBRATION BATH - General
CALSys 250 calibration bath is a highly stable standard stirred liquid bath for calibrating RTDs / Thermocouples and other temperature sensors in the laboratory. The temperature of the bath is set and controlled by a self tuned PID controller with automatic super fine adjustment.

The unit features is portability with very high stability and uniformity. The medium used in the bath is silicon oil.


Specification

·         Temperature Range : 50 to 250 Deg C
·         Temperature resolution : 0.1 Deg C
·         Stability : ± 0.1 Deg C
·         Controlling Sensor : Precision PRT (PT-100)
·         Method of Control : Digital self tuned PID Controller
·         Medium of Heating: Silicon Oil
·         Time to Reach Max Temp : 30 Min.
·         Computer Interface: RS 232
·         Operating Temperature : 20 to 45 Deg C
·         Power Requirement : 230 VAC, 1.5 KW
·         Dimensions : 360(H) x 185(W) x 285(D) mm
·         Tank Dia X Depth : 90 X 140 mm
·         Weight : Approx 12 Kg

Key Features

·         Large Immersion Depths
·         Wide Operating Range (50 to 250 Deg C)
·         High Stability and Uniformity
·         PC interfacing
·         Simple to use and cost effective
·         Portability

Standard Accessories

Silicon Oil ……… Part No. C300S-LB-SO
Reference Standard PRT ……Part No. TPRT-A-300
Carry Case
Operational Manual

Optional Accessories

·         Software for Automated Calibration...Part No. AC-24
·         Silicon Oil………1L-Part No C200S-LB-SO







Trilevel for Forehearth/Distributor
Product Details
In Distributor & Fore-Hearths temperature measurement & control is most important, the glass fore-hearth control system includes a temperature sensing system and control system. The temperature sensing system includes an arrangement of pre-positioned temperature sensors. Simplex thimble thermocouples & tri-level / triplex thermocouples consist of an assembly of a bottom, middle and top thermocouples for sensing the vertical temperature profile of the molten glass at a fixed location. The output signals from these temperature sensors are received by controllers of the control system which then provide control signals & regulate the operation of the heat input devices and the cooling input devices. Thermocouple output & controller''s calibration must be accurate, reliable and repeatable.
The Tri-Level Thermocouples designed to achieve thermal homogeneity of the glass exiting from the fore-hearth for forming, as the homogeneity will help to get the proper distribution of Gob in moulds.

Type
TI/GL/01
Measuring Range
100 To 1600°c
Sensor Type
"R"/ "S"/ "B".
At three levels at B-Bottom, M-Middle,T-Top.
Protection Sheathing
Recrystallised Alumina KER- 710 (C-799) Tube with hole at one end. Special Hardened Platinium / PT Alloy Thimble.
Application
Fore Hearth and Distributor Glass Immersion.


S.No.
Description
1.
SS/Aluminium Connection Head IP-67.
2.
SS Chain.
3.
½" NPT(M) Cable Gland.
4.
Holding Tube : (Inconel - 600/SS310).
5.
Recry. Alumina Outer Tube :- OD X ID to be specified.
6.
Inner Tube suitable to Outer Tube.
7.
6 Bore Recry. Alumina Insulating Tube.
8.
Hardened PT/PT Alloy Thimble :- OD X THK. suitable to Outer Dimension
9.
Ceramic Fibre Insulated Compensating Cable 3/6 Mtrs. long with overall ceramic fiber sleeve.
10.
Quick Release Compensated Connectors "R"/ "S"/ "B" Type.
11.
a,b,c are distances from tip to bottom, middle & top sensor elements depending on the design.

CALSys -15/110
Product Details
Peltier based temperature calibrator - General
CALSys -15/110 offers medium temperature range from -15 to 110 Deg C. It is a highly stable standard temperature source for calibrating thermocouples/RTD. It has peltier elements to generate stable temperature in the well.

The comparison volume is a metallic block of aluminum, which has diameter of 24mm and 120mm depth.

The temperature of the furnace is set and controlled by a self tuned PID controller with automatic super fine adjustment.


Specification

·         Temperature Range : -15 to 110 Deg C
·         Temperature resolution : 0.1 Deg C
·         Stability : ± 0.2 Deg C
·         Controlling Sensor : Precision PRT
·         Method of Control : Digital self tuned PID Controller
·         Time to reach max/min Temp : 25 Mins
·         Computer Interface: RS 232
·         Power Requirement : 230 VAC, 1.5 KW
·         Dimensions : 380(H) x 170(W) x 188(D) mm
·         Insert Construction :
Dia 24mm X 120 mm long
3 x 6mm hole, 115mm insertion depth
·         Weight : Approx 10 Kg

Key Features

·         Wide Operating Range (-15 to110 Deg C)
·         High Stability
·         PC interfacing
·         Simple to use and cost effective

Standard Accessories

Reference Standard PRT.... Part No. TPRT - A - 300
Carry Case
Operational Manual

Optional Accessories

·         Software for Automated Calibration…Part No. AC-24
·         Extra Equalizing Block



Công ty TNHH TM-DV Lâm Gia Phú
Đ/c: 77 Đường số 5, Phường 3, Quận Gò Vấp, TP.HCM, Việt Nam
Tel: 083 588 0828 - Mr Vũ
Fax: 083 588 0829
Email: hoaivu@lamgiaphu.com  ( Mr Vũ : 0909 530 828 )

0 nhận xét:

Đăng nhận xét